Гарантия качества

Triton

GC "Olimp Energy" offers block-modular steam boiler stations with a capacity of 0.5 t of steam per hour. Block-modular steam boiler stations, diesel or gas fueled, are used for heat and steam supply according to the individual customer's needs. Boiler stations can be either modular or constructed as capital or lightweight structures.

Description

The TRITON mobile steam boiler station is designed specifically for areas remote from infrastructure. It is an improved version of the PKN 2M boiler station, which is widely demanded by the exploration and oil and gas industry. Unlike the PKN 2M boiler station, the TRITON steam boiler station is equipped with more modern and reliable equipment, making it more cost-effective to rent in all respects.

The TRITON (formerly PKN 2M) boiler station can be equipped with one, two or three boilers.Diesel, fuel oil or crude oil can be used as fuel.

The set includes:
BASIC CONFIGURATION

 
  •  Boiler house (2 or more boiler units, 2 or more auxiliary equipment units - a spacious frame with painted profiled sheet metal shell structures and mineral wool insulation)
  •  Steam boilers
  •  Automated gas or oil burner with continuous power control
  •  Water treatment module for complete degassing of make-up water with equipment
  •  Pumping equipment
  •  Mains pump (1 - operation, 1 - standby)
  •  Boiler recirculation pump
  •  Expansion vessel
  •  Shut-off and control valves
  •  Visual inspection devices
  •  General automation and safety system
  •  Fire alarm and unauthorized access control system
  •  Automatic fire extinguishing system
  •  Water, electricity and fuel meters
  •  Stainless steel chimney h=5 m


OPTIONS:

 
  •  Installation of additional chemical water treatment
  •  Additional water tank
  •  Consumable fuel tank
  •  Heat exchanger
  •  Control of the frequency of the network pumps
  •  DIOGEN fuel storage complete with fuel pumps, alarm and sprinkler systems
  •  Automated modular container for storage, chemical cleaning and water pressure increase «Aquarius»
  •  PEGAS district heating substations for the supply of heat to high-rise buildings or the supply of hot water.
Technical characteristics
Name Minimum value Maximum value
Steam capacity, t/hour 1 2
Overall dimensions, L/W/H, mm 5 340/2 400/2 800 9 200/3 070/3 200
Maximum fuel consumption, LPH 33 550
Installed/rated electrical power, kW 8,2/4,7 56/39,2
Maximum pressure 4 bar 10 bar
Temperature graph, оС 140 190

GC «Olimp Energy» steam boiler stations have a high degree of mobility. This allows customers to use the modular block steam boiler stations for rent not only as a primary heat source, but also in emergency situations where an additional heat source is required.

 

Steam boiler stations are in great demand in the food and chemical industry, pharmaceutical and medical production, oil and gas production, geological exploration, concrete and asphalt plants and the pulp and paper industry.

 

Steam boiler stations are also often used to heat oil and other fuels and lubricants in winter. Steam boiler stations are widely used for car washes, hotels, cleaning companies, industrial laundries and disinfection of glassware and equipment.

Send a request

And get a FREE on-site visit for on SPECIAL TERMS!